Use; Ventilation Positions; Operating Panel; User Maintenance - J.E. StorkAir WHR 90 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Use

4.1 Ventilation positions

The system can be switched into the following positions using either the three-
position switch (if fitted) in the kitchen or the non-powered extractor hood:
Position 1 low
In this position, the air supply and exhaust fan is set at minimum. This
position can be activated during long-term absence and possibly at night.
Position 2 medium
In this position, the air supply and exhaust fan is set at a normal rate of
revolutions.
Position 3 high
In this position, the air supply and exhaust fan is set at a high rate of
revolutions. Select this position when cooking or showering.
Do not fit a powered extractor hood to this system
The plug should always remain in the socket unless the unit has to
be deactivated due to a serious malfunction or another matter of
urgency. If the plug is removed, mechanical ventilation of the home
will cease and moisture or mould problems may occur in time.
Therefore, you should avoid switching the unit off for longer periods.
Contact your installer in the case of any malfunction. If a malfunction code
can be seen on the display, please contact the installer.

4.2 Operating panel

MENU
OK
toevoer
zomer
aan
tijd
4a.
Display Indication
"1"
Fan position
"2"
Fan position
"3"
Fan position
"xx"
Malfunction code
"-- -- --"
Function unavailable
"."
Bypass open
Function keys
Menu
The installer uses this key to regulate the system and to read off any
malfunctions.
OK
This key is used to confirm chosen values/parameters. OK is used as reset
in the case of filter cleaning.
Intake on
The green led is illuminated when the intake fan is switched on. On warm
summer days, windows and/or doors are often left open. In this situation,
press this key to switch off the intake fan.
Under normal conditions: intake on.
Units with a "bypass" cannot provide night cooling if the intake fan
is switched off. You are therefore advised to keep the intake fan
switched on.
comfort
temp.
"low"
"medium"
"high"
Summertime
Only applies to units with a timer. Without a timer, the display shows
"-- -- --". When summer time is chosen, the green led is illuminated.
This key can be used to switch from summer time to winter time or from
winter time to summer time. The display shows the timer hours.
Comfort temperature
Only applies to units with a "bypass". Without a "bypass", the display
shows "-- -- --". This key can be used to check the set target temperature
and to change it if required. If you wish to change the temperature, press
the
key or the
key until you reached the required value. Now press
the OK key and the new value will be stored in the memory. We
recommend setting the comfort temperature somewhat higher in the
winter than in the summer.

5. User maintenance

5.1 General

Maintenance by the user is limited to periodic cleaning of the filters and
air intake and exhaust valves and replacing the filters annually. Twice a
year, the display on the operating panel will show alternating texts "Fil"
followed by "tER" as a reminder that the filters must be cleaned. It is
recommended that all valves be cleaned at the same time as the filters.
The installation must not be used without filters.
Check the free flow of the condensation drain in and outside the
unit, and the siphon, once a year.

5.2 Cleaning and replacing filters

5a.
Cleaning
• Remove the filters(A) from the WHR.
• Clean the filters with a vacuum cleaner: if moist, rinse them clean in
lukewarm water with a neutral soap solution.
• Slide the filters back into the WHR.
• Press [OK] on the operating panel.
Replacement
• Replace the filters once a year.
• Remove the filters(A) from the WHR.
• Remove the two clips which attach the filter cloth to the filter holders.
You can now slide the filter cloth out of the holder.
• The new filter cloth can then be slid into the holder. Fit the two clamps
back on.
• Slide the filters back into the WHR.
• Press [OK] on the operating panel.
30
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Whr 91

Table des Matières