1A
1B
1C
7.3
PRO G RA M MING
H OT WATER D OSES
To programme the final hot
water temperature, proceed
as follows:
Press and hold the 1A and
1
1C buttons for 5 seconds,
to enter the first level pro-
gramming menu. Access
is confirmed when the
button 1B LED light starts
blinking.
Press button 1B to enter
2
the second level pro-
gramming
menu
cess is confirmed when
the
message
"dS"
shown on the display and
button 1B starts blinking).
3
Programming
place by operating the
lever.
4
Push the upper part of
the lever to programme
the first dose of hot wa-
ter (key 1). Push the low-
er part of the lever to
programme the second
dose of hot water (key
key 1
key 1
key 2
key 2
The delivery seconds are not
visible on the display.
5
To stop delivery, release
the lever, which will return
to the rest position.
To confirm and exit, press
6
the
central
twice.
7.4
EASYCREAM
TEMPERATURE
(ac-
PROGRAMMING
(OPTIONAL)
is
To programme the Easy-
cream final temperature:
Press and hold the 1A and
takes
1
1C buttons for 5 seconds
to enter the first level pro-
gramming menu. Access
is confirmed when the
center button starts blink-
ing.
Press button 1B to enter
2
the second level pro-
2).
gramming
cess is confirmed when
the
message
shown on the display and
button 1B starts blinking).
E AG L E O N E P R I M A | L I B R E T TO I ST R UZ I O N I - U S E R H A N D B O O K - M A N U E L D 'I N ST R U CTI O N S | 5 4
key 1
key 1
key 2
key 2
Programming
3
place by operating the
lever.
4
Push the upper part of
the lever to enter the fi-
nal
gramming of the first
1B
Easycream recipe (key
button
1). Push the lower part of
the lever to enter the final
temperature
ming of the second Easy-
cream recipe (key 2).
Decrease or increase the
5
temperature by press-
ing buttons 1A and 1C re-
spectively; the tempera-
ture is shown on the unit
display. It is also possible
to set the half degree
(which can be viewed
from the subscript shown
on the display).
6
To confirm and exit, press
the
central
twice.
menu
(ac-
"dS"
is
takes
7.5
M ACHINE U PDATE
1
temperature
pro-
2
3
program-
4
5
6
1B
button
1A 1B
Place
the
update
file
".hex"
into
the
folder
"nuovas";
With the machine switch
OFF, insert the USB sup-
port;
Switch ON the machine.
The buttons start flashing
until the machine will be
in standby mode;
Switch off the machine;
Switch ON the machine
and do the reset of the
parameters pressing and
holding the buttons 1A
and 1B until on display will
appear the written "dP"
(default parameters).
Switch OFF the machine
for 10 seconds and then
switch it on again.