Electrical connections
Cable connection, 2-wire
- area
Pamb
Ub+/S-
1
Ub-/S+
2
1: white, - 2: gray
Attention !
To avoid interruption of pressure compesation to ambient pressure
the connecting cable with capillary must not be pinched or bended!
min. bending radius: fixed installation = 20mm
min. bending radius: flexible installation = 100mm
Level Probe
4
outside
L+
power supply
M
consumer load
Protective
polyamid
Suspension for level probe
Order No.:405 781
Nameplate
D r u c k m e s s u m f o r m e r
Typ xx.x
Messbereich: XXXXXXXXXXXXXX
Reg.-Nr.: XX XXXX. XX. 01
Klasse: 0.3
Klemme 1: +Ub / -S
Klemme 2: -Ub / +S
- area
Einbaulage:
II 2G Ex ia IIC T4/T6 Gb
II 2D Ex ia IIIC T135°C Db
B VS X X AT E X E X X X X
MANFRED JÜNEMANN
Mess - und Regeltechnik GmbH
D-32107 BAD SALZUFLEN
Avoid damage to the nameplate, the order/production
number must remain legible in order to ensure traceability!
Cable box IP 67 with pressure com-
pensation to the atmosphere
xxxx
: 4 ... 20 mA
: 20 ... 30 VDC
Production Number
Job Number
T
: -20°C ... 0 ... +70°C T4/T135°C
a
Year of manufacture
-20°C ... 0 ... +40°C T6
Attention !
Order No.:101 524
Quality for the
future