Switch the machine off by pressing the power on/off switch (Fig. 14).
•
Empty and rinse out the used capsule drawer and drip tray (Fig. 6).
•
Remove and empty the water tank (Fig. 5).
•
Mix the contents of a bottle of Caffitaly System descaling agent with approximately 750
cc. of water (a total of 1 litre) and pour into the tank.
•
Place a container (at least 1 litre) under the dispensing spout and the hot water dispensing
pipe (Fig. 19).
•
Make sure that the lever is lowered (Fig. 3) and that there is no capsule inside the capsule
compartment.
•
Turn the control lever forwards (Fig. 20).
•
Press and hold buttons A and B while switching the machine on by pressing the power
on/off switch.
•
Button B will light up, while warning light D blinks YELLOW and RED alternately.
Press button B to start the descaling cycle.
•
•
The machine dispenses the descaling solution at specific intervals (5 doses with a 4
minute pause between each one, for a total duration of about 25 minutes). During
this step, when the buttons must not be pressed, warning light D blinks YELLOW and
RED alternately.
We recommend emptying the used capsule drawer after the first dispensing cycle, to
prevent any water from overflowing.
•
When the first step is over, button B lights up and the machine beeps repeatedly. The
water tank is empty.
•
Carefully rinse out the water tank and refill it with fresh water (Fig. 4).
•
Empty and rinse the used capsule drawer, the drip tray and the container used and put
them back in position (Fig. 6).
•
Press button B to start the rinse cycle.
•
Rinse water (about 500 ml) will be run through the machine. During this step, warning light
D blinks alternately (twice YELLOW and twice RED).
•
When the rinse cycle is complete, the machine beeps and Warning light D is lit steadily
in ORANGE.
•
Set the control lever back to its central position (Fig. 21).
•
The buttons A-B-C blink simultaneously; the machine is warming up. When the buttons
turn on and remain steadily lit, the appliance is ready for use.
•
Carefully empty and rinse out the water tank and refill it with fresh, still water (Fig. 4).
•
Empty and rinse out the used capsule drawer and drip tray (Fig. 6).
24
English