High temperature automatic shutdown
Water temperature above 185° F (85° C) for ten (10)
E4
seconds. The controller has automatically closed
the electromagnetic valve and unit is shut down.
Overheating occurred
1.
Possible causes include operating at a very high
load for a long period followed by a sudden
E5
event such as excessively low pressure in water
supply or excessively high gas supply pressure.
2.
The thermal fuse has failed due to safeguarding
against overheating.
Solenoid valve error
1.
The wiring is loose or a bad connection
occurred.
E6
2.
The solenoid valve is faulty.
3.
Controller has failed.
Blower fan system error
1.
The blower jammed or stopped operating
because of a foreign object.
2.
The blower fan suffered a mechanical break-
down.
E8
3.
The fan power control module has broken
down.
4.
Wiring harness or wiring connection some-
where in fan connection has come loose.
5.
The pressure vent is jammed.
6.
The pressure switch is damaged.

INSTALLATION

INSTALLATION GUIDELINES

Only properly qualified personnel should install this equipment. Improper installation or installation by a
non-qualified installer may void warranty. Failure to comply with state, provincial and local codes pertaining
to water heater installations may also void warranty.
This appliance shall NOT be installed outdoors.
The appliance and its gas connection must be leak tested before placing the appliance in operation. A qualified
installer or service technician should inspect and leak test system before use.
The installation must comply with local codes. In the absence of local codes, the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1 shall prevail. If installed in
a manufactured home, the installation must conform to the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280 or the Canadian Standard CSA Z240 MH Series, Manufactured Homes.
onsenproducts.com
onsenproducts.ca
SOLUTION
Normal safety precaution to protect against a rare
occurrence in which water flow is dramatically
reduced causing a small slug of very hot water.
1.
Normal system function. This should be a very
infrequent event. Correct gas or water supply
issues if there are frequent reoccurrences.
2.
Replace the thermal fuse.
1.
Mount plug-in wiring properly and replace bad
elements.
2.
Replace solenoid valve.
3.
Repair or replace the controller.
1.
Remove foreign object and eliminate the cause
that led to a jammed fan.
2.
Replace the blower fan.
3.
Replace control board.
4.
Plug the plug-in element in place, or replace the
bad element.
5.
Replace and/or clean the vent.
6.
Replace the pressure switch.