Overview of possible operating and error messages
If an error occurs, the motor switches off permanently. Exception error: "Undervoltage". The motor automati-
cally switches back on as soon as the voltage lies over 209V for at least 6 seconds.
If an error occurs, the system must be disconnected from the power supply and the motor must be reset.
An overview of possible error codes will help to determine the fault.
Code number
E- 01
E- 02
E- 03
E- 04
E- 05
E- 10
E- 11
E- 13
E- 16
E- 20
E- 21
E- 22
E- 31
E- 41
E- 42
E- 51
E- 60
E- 61
E- 62
E- 63
E- 66
Content
DC bus over voltage
DC bus under voltage (alarm only, without motor stopping)
DC bus low voltage (motor stops)
Software level power module over current protection
Hardware level power module over current protection
Motor overload protection (electronical thermal protection)
Motor over speed protection
Power module over temperature
Motor step out
Earth short circuit
Phase short circuit
Output phase open circuit
Communication error with masterboard
Current sampling circuit error
Starting current/relay error
Power modul thermal sensor error
Motor blocked
Digital signal progressing on-chip ROM error
Digital signal progressing on-chip RAM error
Digital signal progressing, error, program out of control
Communication error with control box