11. Motor display controler
The pump has a permanent magnet motor and is electronically protected against overload
Note
The motor speed is switched on using the manual button. The switch contacts and the assigned speed
are activated.
If the pump starts from a standstill, it starts up in priming mode and subsequently with the selected fi xed
speed.
During running operation the pump is started up at the fi xed speed directly, without priming time.
Note
Installing a fl ow monitor in the circulation line is recommended so that a failure message can be dis-
played. In this way a lengthy interruption of the bath water circulation can be prevented.

Default setting:

Speed:
Priming speed:
Priming time:
Speeds which can be set:
Priming time which can be set:

User interface

LED display: displays the current
(1)
speed of the motor.
"SET" button: used to enter the program-
(2)
ming mode or to reset the control.
Button "1/ ": used to select the fi xed
(3)
speed/to change the programming mode.
Button "2/OK": used to select the fi xed
(4)
speed/to save the programming mode.
Button "3/ ": used to select the fi xed
(5)
speed/to change the programming mode.
Button "0": used to stop the motor.
(6)
| 20
3 = 2850 min
-1
2 = 2400 min
-1
1 = 2000 min
-1
= 2850 min
-1
= 5 minutes
1000 - 2850 min
(in 50 min
-1
0 - 10 minutes (in 1 minute steps)