aqua technix AQUA VARIO Plus OKU Instructions De Montage Et D'utilisation page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electricity
When working on the electrical unit, there is an increased risk of electrocution due to the damp
surroundings.
Incorrectly installed protective conductors can also lead to electrocution for e.g. as a result of oxidation or
cable breakage.
• Make sure that the swimming pool and its surrounding protective zone are installed,
commissioned and operated in accordance with the relevant local regulations.
• Before working on the electrical system, take the following precautions:
- Disconnect the system from the electrical power supply.
- Attach a warning sign: "Do not switch on! Work in progress on the system."
- Be aware of the discharge time for the condenser: wait minimum 15 minutes after disconncting the
power supply and before starting work on the system.
- Check the absence of voltage.
• Regularly check that the electrical system is in proper working order.
Hot surfaces
Risk of burns - the electric motor can reach temperatures of up to 70 °C.
- Do not touch the motor while it is running.
- Let the motor cool down before working on the pump.
Caution
3. General
Please take the necessary precautions when transporting the pump. During transportation, avoid inter-
mediate storage in a damp location or locations subject to significant temperature fluctuations. The splash
pumps have been designed for the circulation of swimming pool water.
Most plastic components that come into contact with the pumping medium are made of reinforced poly-
propylene (PP) and thus are highly resistant to corrosion by pool water. The water temperature must not
exceed 60 °C.
Non-compliance with our installation and operating instructions will void any warranty.
4. Installation
Caution
The installation site of the pump must be dry and well ventilated.
When installed in a closed room, a drainage connected to the
sewers must be installed.
The size of the floor drain depends mainly on the size of the swim-
ming pool and the circulation flow rate but also on possible leaks
within the pool water circulation system.
The ambient temperature must not exceed 40 °C.
15 |

Publicité

Table des Matières
loading

Table des Matières