Caution
When the pump is installed outside, we recommend providing
simple protection against the weather (rain, sun etc.).
Caution
Implement appropriate measures to attenuate the noise genera-
ted by the pump to avoid damage to the environment. Fastening
the pump to the foundation should be effected exclusively by me-
ans of bolts, threads or dowels, in order to avoid blocking the
removal of the motor unit! Make sure that there is enough space
between the fan cover and the wall, minimum 50 mm. You also
need enough space to permit disassembly of the strainer basket,
minimum 210 mm above.
The pump should be installed at water level
or below water level and in a horizontal posi-
tion, in order to keep the suction path as
short as possible and to reduce head loss.
The Aqua Vario Plus OKU is self-priming
and should never be installed more than 2 m
above water level. Make sure that the suc-
tion line is not leaky, otherwise the pumps
will prime insufficiently or not at all. We
recommend the installation of check valves
and shut-off valves, according to the type
of pump or plant. The adhesive bonds at
the suction and pressure lines require
more time to cure, allow at least 12 hours
before starting the pump.
| 16