Air filter cartridge:
Depending on the working time and the surrounding of the humidifier, the cartridge
should be replaced from time to time because it decreases the mist level.
Aroma cartridge:
To receive scented mist, you can put some drops of scented oil onto the fleece.
Tipps:
∙ Fill in lukewarm water into the tank and not the basin. Please wipe if some water
drops may form on the housing because the housing might become splotchy.
∙ Please empty the device if the room temperature is below 0°C. The building of ice
damages the membrane.
∙ Do not transport the device if too much water is in the basin. Unplug the device
and empty some water.
∙ Do not put any chemicals, detergent, metal etc. into the basin.
Troubleshooting
Failure
Possible Reason
Power light
No Power
works not
Light is on but
No water in tank
no mist
Smell
Dirty or old water
Light is on, the
Too much water in
appliance
the water tank
does not work
Low mist level
Scale on the mem-
brane
Attention: Unplug first if the device should be opened.
Solution
Please check if the unit is plugged in and
the power button is pressed.
Fill water in the tank.
Check if the water tank is attached correctly.
Clean the tank and the base completely
and let it dry open at least 2 hours
Fasten the tank lid and take out some water
from the basin.
Clean the membrane and refill with new
water.