P r i m i n g
P r i m i n g P ro c e d u r e
DISCONNECT THE TOOL FROM THE AIR SUPPLY OR SWITCH OFF AT VALVE 70.
All operations should be carried out on a clean bench, with clean hands in a clean area.
Care MUST be taken at all times, to ensure that no foreign matter enters the tool, or serious damage may result.
•
Remove Bleed Screw 85 and Bonded Seal 84.
•
Connect air supply to tool and switch ON/OFF Valve 70 to 'ON" position.
•
Invert tool over suitable container and actuate trigger. Waste oil will be ejected through the bleed screw hole.
CARE SHALL BE TAKEN TO ENSURE THAT THE BLEED HOLE IS NOT DIRECTED TOWARDS THE OPERATOR OR OTHER
PERSONNEL.
•
Disconnect air supply to tool or switch ON/OFF Valve 70 to 'OFF" position.
•
Fill the priming pump with oil.
•
Screw priming pump 07900-00700 into the bleed screw hole with Bonded Seal 84 in place.
•
Actuate the priming pump by pressing down and releasing several times until resistance is felt.
•
Remove the priming pump.
•
Replace Bleed Screw 85 and Bonded Seal 84.
•
Connect air supply to tool and switch ON/OFF valve 70 to 'ON" position.
•
Check that the stroke of the tool meets the minimum specification of 30 millimetres. To check the stroke, measure the distance
between the rear of the tail jaw cylinder and body mouldings, BEFORE pressing the trigger and when the trigger is fully actuated.
The stroke is the difference between the two measurements. If it does not meet the minimum specification, repeat the priming
procedure.
Item numbers in bold refer to the general assembly drawing and parts list on pages 26-27.
I M P O R T A N T
Ensure that the new oil is perfectly clean and free from air bubbles.
29