Troubleshooting
Troubleshooting list for some common electrical problems may happen
during use:
Phenomenon
* The fixture does not work
* No light out
* Fan not work
* No display
* No responding to DMX
controller
* Signal error while use DMX
FOR ANY PROBLEM OR MALFUNCTION, PLEASE CONTACT YOUR RESELLER
Maintenance
● Clean with soft cloth using normal glass cleaning fluid.
● Always dry the parts carefully.
● Clean the external optics at least every 20 days.
● Clean the internal optics at least every 30/60 days – Up to vary products.
*Check main power fuse & power cable
connection
*Measure main voltage on the main connector
*Check connection of display PCB
* Contact your reseller
*Check working mode setting on display is DMX
mode or not
*Check whether the unit be set as SLAVE
*Check DMX address settings
*Check DMX cable and it's connection
*Try to use another DMX console
*Check whether DMX cables be
connected well or not
* Check whether the DMX cable has to be
terminated with a terminator to reduce signal
errors. If not, please Solder a 120-ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+)
into a 3-pin XLR-plug and plug it in the
DMX-output of the last fixture
The cleaning of internal must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates:
damp, smoky or particularly dirty surrounding can cause greater accumulation of
dirt on the fixture's optics.
Solution