3.3) Storage
After completion of the work release the oil pressure by pressing the release push button and
make sure that the ram of the head connected is completely retracted.
– Switch off the pump by the ON-OFF switch (IG), selecting position "0".
– Disconnect the pump from the mains supply for long periods of inactivity.
4. WARNING
The pump is robust, completely sealed and requires very little daily maintenance.
Compliance with the following points should help to maintain the optimum performance of the unit:
– Avoid dirty surfaces: dust and sand are a danger to any hydraulic equipment.
– The mains supply cable must be in perfect conditions and correctly installed other it must be
replaced immediately.
Should it be necessary to extended the mains cable, use 3 core (2 phases+earth) cable of suitable
section.
Never pull the cable to disconnect it from the mains supply.
Keep the cable may from heat, oil and sharp edges.
– Store the pump in a clean, dry environment.
4.1) High pressure flexible hose
– Before using the pump, check that the flexible hose and couplings are not damaged.
– Before disconnecting the hydraulic head from the hose, make sure that the ram is completely
retracted.
– Do not bend or kink the hydraulic hose.
– Keep the pump and flexible hose away from naked flames and sources of heat above 70°C.
– The factory fitted spring steel, spiral guards must be in place at each end of the flexible hose.
– Do not touch the flexible hose when under pressure.
– When using the pump, the flexible hose must be uncoiled and laid out straight.
5. MAINTENANCE
Never open the electrical panel cover or effect any maintenance operation when the pump is
connected to the mains supply.
Should replacement of pump components be necessary, always use original spare parts.
After every use, the pump and accessories must be wiped with a clean cloth, taking care to remove
any residue, especially around the sockets, quick couplers and inside the protective caps.
It is possible to check working pressure with the MPC1 gauge available as an optional accessory
(see page 38).