Ingeteam
Communication ring:
Modem
A maximum of 10 units can be interconnected.
5.2.2. GPRS/3G remote communication via USB modem
1.
Connect the communications card to one of the charging stations located at one end of the installation in
order to start the communication ring. It can be connected both with the J15 and J17 connectors, as well
as the J16 and J18 connectors.
Remove the end of line jumper from the control card:
2.
Connect the wiring that joins the control card to the communications card (see the light grey cabling in
the following figure).
Connect the USB modem to the communications card to obtain the GPRS/3G connection (see the white
cable in the figure below).
28
First station
Pin
Colour
1
White/Orange
2
Orange
INGEREV CITY Wall, INGEREV CITY Ground
Intermediate station
Control card jumper
Signal
RS-485 B (+)
RS-485 A (–)
ABA2017IQM01_A - Installation and Operation Manual
Final station