Télécharger Imprimer la page

Ingeteam INGEREV CITY Duo Manuel D'installation Et Usage page 34

Masquer les pouces Voir aussi pour INGEREV CITY Duo:

Publicité

Les langues disponibles

Les langues disponibles

Ingeteam
5.
Connect the wiring that joins the control card to the communications card (see Cable E, light grey cabling
in the following figure).
To wire the communications card and control card at the station, you must keep in mind the following
connection positions:
The jumper of the communications card, marked as F in the previous figure, remain in place.
4.
Connect the charging stations that make up the communication ring from the back, as indicated in the
following figures. In the first station, the RJ45 connector on the left is used to start the communication
ring (G) and the connector on the right to connect the modem (H).
First station
G
H
34
Pin
Colour
1
White/Orange
2
Orange
Intermediate station
F
E
Signal
RS-485 B (+)
RS-485 A (–)
Final station
ABA2017IQM01_A - Installation and Operation Manual