2.
Connect the communications card with the Ethernet connection on the J15 and J18 connectors of
the control card. The end of line JP1 jumper on the station´s control card where it connects to the
communications card must be removed.
32
A
A.
B.
C.
Jumper JP1 of the uninstalled control card
Communications card
Control card on the charging station