For correct application of the food safety
system (HACCP), please follow the instructions
in this
paragraph.
Washing must be carried out using original
"Service Line" products, see details on the
last page. Any other product could make the
materials in contact with food unsuitable.
Cleaning dispensing unit
This operation must be made on all the groups at the
end of each working day
1) Using a brush, clean the cover gasket.
2) Insert the rubber disk into the filter-holder with its filter.
3) Pour in a packet or dosing cupful of detergent powder
4) Attach the filter-holder to the dispenser unit and make
a few coffee cycles.
5) Remove the filter-holder and clean the shower with a
sponge.
6) Flush each dispenser unit with water for about 30
seconds.
Do not remove the filter holder during coffee
dispensing.
Filter-holders
1) Put a liter of cold water in a suitable container and add
detergent.
2) Remove the filters from the filter-holders.
3) Soak the filters and the filter-holders in this solution for
about 15 minutes.
4) Remove any residue with a sponge and rinse well with
cold water.
5) Place the filters back in the filter holder, making sure
that the anchoring spring of the filter is in its slot
Steam and hot water dispensing pipes
Using a clean sponge, wash with hot water removing any
organic residue present. Rinse carefully.
To clean the inside of the steam nozzle, follow these steps:
Turn the nozzle towards the cup tray and carefully activate
steam dispensing at least once.
16. Cleaning and maintenance
Grille and Drip Basin
Remove the grille from the basin, extract the grille sections
and complete the cleaning operation under running water.
Discharge Basin
At the end of the working day, pour about a liter of hot water
into it to remove any discharge residues.
Bodywork
Use a soft cloth and cleaning products WITHOUT ammonia
or abrasives, removing any organic residue present in the
work area.
N.B. Do not spray liquids into the panel slots.
11 EN
1
2
3