TOUJOURS INSTALLER LE RÉCEPTEUR À L'INTÉRIEUR DE LA BOÎTE DE JONCTION MURALE FOURNIE (À FAIBLE VOLTAGE) ET EN-
1. Add two male spade connectors to the end of the 10 foot 2-wire harness (Black & Red)
installed with P33S.
2. Install the J-Box to the framing, at desired location within 10ft from fi replace.
3. Feed the 2ft wire harness through the opening at back of J-Box, Connect the black & red wires to the two wires from the (2 foot) SIT Profl ame
GTMF wire harness, (TH green) & (TP/TH White) other wires will not be used.
4. Connect the wiring harness to the back of the receiver.
5. Install the Receiver in the Low Voltage Junction box, supplied with P33S.
6. Insérer 4 piles AA dans le compartiment des piles en respectant la polarité
7. Poser le bouton de l'interrupteur coulissant sur la plaque murale.
8. Le maintenir à la position « OFF » pour que l'alignement se fasse correctement.
9. Placer la plaque face au récepteur de façon à ce que les mots « ON » et « UP » soient du même côté
10. Aligner le bouton et l'interrupteur du récepteur et les emboîter l'un dans l'autre.
11. Aligner les trous de vis.
12. Fixer la plaque au récepteur à l'aide des deux (2) vis fournies
34
INSTALLATION DU RÉCEPTEUR ET COMMUTATEUR MURAL
I
MPORTANT INSTALLATION NOTE:
CASTRER CELLE-CI DANS LE MUR.
NE PAS INSTALLER DANS L'ESPACE PRÉVU POUR LOGER L'APPAREIL.
Installation murale
REFEREZ-VOUS AUX INSTRUCTIONS DE
CODAGE DANS CE MANUEL
Fils supplémentaires
non utilisés
Fil blanc
.
bouton
Connecteur de beche
Fil vert
Regency
®
P33S Foyer à évent direct à dégagement zéro
boîte de jonction à faible
voltage
récepteur
plaque
Fil rouge
Fil noir
Jboîte de
jonction