PROGRAMMING: control panel waits for commands for the operating time memo-
rizing procedure. See par. 8.2.
Warning: you may get access to programming only if control panel is at feed or at
closed, not during a working cycle.
8.2 Operating times learning
1. Execute wirings to terminals, control panel must not be at feed, manually place the door at half run;
2. Set DIP1=ON and DIP2=ON and apply power supply: the flashing light flickers: the control panel is
ready for the programming;
3. Give a START input: (by push-button panel or remote) door starts opening;
4. Once the door reaches the point of complete opening, give another OPEN impulse: the door stops;
5. Give another START input: door starts again to close;
6. Once the door reaches the point of complete opening, give another OPEN impulse: the door stops
and the flashing light is fixed;
7. Adjust the dip switches as desired according to the operating program and exit the programming (see
Table 2): the LED is switched off and the learning of operating times is finished. The following cycle will
be executed according to the selected operating program.

8.3 Radio receiver

211ER control board includes a 433,92MHz built-in radio receiver accepting both transmitters with
HCS coding (complete rolling code or just part fixed), and HT12E dip-switch coding. The receiver memory
capacity can contain up to 40 different transmitters.
It is possible to choose, according to one's needs, which key of the memorized transmitters will activate
the open input and which one will activate the close input. Procedures for the memorizing and deleting of
the remotes are explained as follows.
Memorization of transmitters:
1. Cut off and then apply power to the control panel or ensure it has finished a closing cycle and it's
ready to receive instructions;
2. Press S2 key on the control panel and continue pressing it (by keeping it pressed the receiver is lear-
ning);
3. Press the key you want to link to OPEN input: flashing light blinks (in case you don't want to link any
channel to open input, go directly to point 5);
4. Press the key you want to link to CLOSE input: flashing light blinks (in case you don't want to link any
channel to close input, go directly to point 5);
5. Repeat points "3" and "4" for other remotes by keeping S2 pressed;
6. Release S2 key: learning completed.
WARNING: if the S2 key is maintained pressed for 30 seconds without any remote being learnt, a reset
procedure of the remote memory is started up!! See "Deletion of transmitters".
Deletion of transmitters:
1. Cut off and apply power to the control panel or ensure it has completed a closing cycle and it's ready
to receive instructions;
2. Press S2 key on the control panel and continue pressing it: after 30 seconds the flashing light turns
on.
WARNING: during this period, ensure that any remote doesn't transmit.
2. Keep S2 key pressed: after 15 seconds the flashing light blinks;
3. Release the key S2: memory cancelled.