Assembly And Wiring Instructions; Operating Instructions; Learning Of Working Times; Description Of Functioning Program - Dea 211E Notice D'emploi Et Avertissements

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operating instructions and warnings
only for qualified personnel
WARNING Using the product under unusual conditions not foreseen by manufacturer may cause
dangerous situations; this is the reason why all the conditions prescribed in these instructions must be
followed.
WARNING Under no circumstance must the product be used in an explosive environment or sur-
roundings that may prove corrosive and damage parts of the product.
7

ASSEMBLY AND WIRING INSTRUCTIONS

Connect to the power supply 230 V ~ 50 Hz through a multi pole switch or a different device that can
ensure multi pole disconnection from the power supply, with a contact opening of 3,5 mm. Use a cable
with a minimum section of 3 x 1,5 mm² (e.g. a H07RN-F type).
1-2
230V ~ 50Hz power supply input (L=phase, N=neutral)
L
N
230V ~ 50Hz motor output max 500W (3=open, 4=common, 5=close)
3-4-5
Input for N.O. closing push-button or N.C. photocell contact (this input may be used
in different way depending on the selected program. See par. 8.1)
6
WARNING: the control panel doesn't foresee an exit for auxiliary power supply. The
eventual photocell has to be separately powered.
7
Input for opening push-button
8
Common inputs
COM
9
Antenna signal (only for art. 211ER)
10
Antenna ground (only for art. 211ER)
8

OPERATING INSTRUCTIONS

8.1 Description of operating programs
This control panel contains 3 different operating programs and a programming mode to memorize
the operating time; these programs can be selected by dip-switch no.1 as indicated in table 2.
WARNING: once the operating time is selected, cut off and re-apply power supply.
DIP1
DIP2
OFF
OFF
MAN PRESENCE: open command maintained pushed
maintained pushed
ON
OFF
STEP BY STEP with SEPARATED OPEN/CLOSE: open impulse
stop, close
8
or closing cycle, any open or close command is activated, the operator stops at
working time expire. No automatic closing foreseen.
OFF
ON
STEP BY STEP with PHOTOCELL: open impulse
closing, open
is activated (photocell contact) the door reverses its run. If during the opening or
closing any open impulse or photocell are activated, the operator stops at working
time expire. No automatic closing foreseen.
WARNING: remember to bridge CLOSE input (Photocell) towards the common if
not in use.
WARNING: the control panel doesn't foresee an exit for auxiliary power supply.
The eventual photocell has to be separately powered.
Table 1 terminal boards connection
Table 2 operating programs
PROGRAMS
closing. Door stops at command release
opening, open
stop, open
stop, open
opening... If during the closing cycle the close input
opening, close command
opening, close
opening... If during the opening
opening, open
stop, open
A2
A3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

211er

Table des Matières