SPECIFICATION
CHARGER
Model
Charging voltage
Weight
APPLICATION
For charging the HiKOKI BATTERY
○ BSL1415S,
BSL1415,
BSL1430,
BSL1440,
BSL1815Χ, BSL1820, BSL1825, BSL1830, BSL1840, BSL1850
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect
the
charger's
receptacle.
When connecting the plug of the charger to a
receptacle, the pilot lamp will blink in red (At 1-second
intervals).
Table 1
Before
charging
While
charging
Charging
complete
Pilot lamp
(red)
Overheat
standby
Charging
impossible
(2) Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the Table 2, and batteries that have become hot should
be cooled for a while before being recharged.
Table 2
Rechargeable batteries
BSL1415S,
BSL1415,
BSL1430,
BSL1440,
BSL1450,
BSL1815Χ, BSL1820, BSL1825, BSL1830, BSL1840, BSL1850
(3) Regarding recharging time
Table 3 shows the recharging time required according to the type of battery.
Table 3 Recharging time (approx. min.) at 20°C
Battery
Voltage
1.3 Ah
(V)
BSL1415S
35
14.4 V
BSL1415X
(4 cells)
min.
BSL1815S
35
18 V
BSL1815X
(5 cells)
min.
BSL1415Χ,
BSL1420,
BSL1425,
BSL1450,
BSL1815S,
BSL1815,
power
cord
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
Blinks
Lights for 0.5 seconds. Does not light
for 0.5 seconds. (off for 0.5 seconds)
Blinks
Lights for 1 second. Does not light
for 0.5 seconds. (off for 0.5 seconds)
Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (off for 0.1 seconds)
BSL1415Χ,
BSL1420,
BSL1425,
BSL1815S,
BSL1815,
1.5 Ah
2.0 Ah
BSL1415
40
BSL1420
min.
(4 cells)
(4 cells)
BSL1815
40
BSL1820
min.
(5 cells)
(5 cells)
UC18YKSL
14.4 V – 18 V
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 1.
3. Charging
When inserting a battery in the charger, the pilot lamp
will light up continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red (At 1-second intervals). (See
Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
to
the
Table 1, according to the condition of the charger or
the rechargeable battery.
Temperatures at which the battery can be recharged
Battery capacity (Ah)
Li-ion BATTERY
2.5 Ah
60
BSL1425
75
BSL1430
min.
(4 cells)
min.
(8 cells)
60
BSL1825
75
BSL1830
min.
(5 cells)
min.
(10 cells)
0.35 kg
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
Malfunction in the battery
or the charger
0°C – 50°C
3.0 Ah
4.0 Ah
90
BSL1440
120
min.
(8 cells)
min.
90
BSL1840
120
min.
(10 cells)
min.
English
5.0 Ah
BSL1450
150
(8 cells)
min.
BSL1850
150
(10 cells)
min.