11.
Parameter List
Parameter
Value
1
Language
english
2
Password
0 - 9999
3
Statistics
dosing hours tubing hours
4
Max flow rate
0.1 –
100.0%
5
Pump Function
Manual
Mode
6
Alarm Relay
N. Open
7
Level Alarm
Stop
8
Buzzer
ON
9
Unit
ml/h
10
Trigger
No Trg
11
Density
0.50-2.00
12
On Time
0-10000
13
Off Time
0-10000
14
Delay Time
0-10000
15
mA for 0%
0.0-20.0
16
mA for max
0.0-20.0
17
N
1-1000
18
pulse
1-2000
19
liter
1-2000
20
Chem. Conc.
1-100
21
ppm
0-3000
22
memory
ON
23
quantity
0-30000
24
time
0-10000
25
Flow rate
Calibr.
12.
Dosing parameter Table
Mode
Param 1
ON Time sec
Manual
(0-10000)
mA Input for
Direct or Inverse
min dosing
mA
(0.0-20.0 mA)
Set Point
PPM
(1-3000 ppm)
Quantity
Batch
(1-30000ml)
PROP 1:N
(1-1000)
PROP N:1
(1-1000)
Default parameters are typed bold and underlined
13.
Alarms Table
alarm
dosing
Tube Break
stop
Level
Stop if selected
Motor
stop
0000137630
Value
Value
german
italian
liters
mA Mode
Batch Mode
N.Closed
Run
OFF
L/h
%
Trg 1
Trg 2
OFF
Param 2
OFF Time
DELAY Time
sec
sec (0-10000)
(0-10000)
mA Input for
max dosing
(0.0-20.0 mA)
Flowmeter
factor
(1-2000 pul /
1-2000 Lit)
Time sec
(1-10000)
N
N
Display
TUBE BREAK
LEVEL
MOTOR
Rev. 4.2
Value
french
1 :N Mode
Trg 1&2
Param 3
Memory
CHEM.
MEMORY
CONC.
(ON-OFF)
(1-100%)
MEMORY
(ON-OFF)
MEMORY
(ON-OFF)
MEMORY
(ON-OFF)
buzzer
ON if selected
ON if selected
ON if selected
Value
Value
spanish
N :1 Mode
Ppm Mode
Max flow
Trigger
rate
TRIGGER
MAX FLOW
(No Trg/Trg
RATE
1/Trg 2/Trg
(0.1 –100%)
1&2)
TRIGGER
MAX FLOW
(No Trg/Trg
RATE
1/Trg 2/Trg
(0.1 –100%)
1&2)
TRIGGER
(No Trg/Trg
1/Trg 2/Trg
1&2)
TRIGGER
(No Trg/Trg
1/Trg 2/Trg
1&2)
TRIGGER
(No Trg/Trg
1/Trg 2/Trg
1&2)
solution
Relay
Replace hose, clean
the contacts and
ON if selected
power cycle the
Restore the level of
ON if selected
the chemical
product
ON if selected
Check the pump
Default
english
0 (disabled)
100.0%
Manual Mode
N.Open
Stop
OFF
ml/h
No Trg
1.00
10
0
0
4.0
20.0
1
1
1
100
100.0
OFF
100
100
\
Density
DENSITY
(0.50 – 2.00
kg/L)
1.00
DENSITY
(0.50 – 2.00
kg/L)
1.00
system
16