Mains cable
The appliance will be delivered with a
5-wire mains cable (length: 150 cm)
for connection to 3-phase alternating
current with neutral conductor.
Fuses and switches are not included in
the scope of supply.
Warning
Risk of electric shock and risk of fire!
No extension cables, no multi-coupling
and no plug-in, mobile time switches
may be used.
Do not use plug-in, mobile timer
switches. The machine may not be
connected via an external switching
mechanism, which regularly switches
the machine on and off (e.g. timer
switch).
L 1 brown
L 2 black
L 3 grey
N blue
P E yellow-green
400 V 3 N ~
L3
L2 L1 N
L3 L2 L1 N
Heating
Motor
Pump
Fuse
230 V 1 N ~
Reduced mains power
L3
L2 L1 N
L3 L2 L1 N
Heating
Motor
Pompe
Fuse
PE
PE
4,6 kW
0,4 kW
0,1 kW
10 AT
PE
cut off L3 and L2
PE
1,8 kW
0,4 kW
0,1 kW
10 AT
EN 35