CoolMatic CRP-40
For safety reasons the refrigerator is equipped with an electronic system to
prevent the polarity being reversed. This protects the refrigerator against re-
versed polarity when connecting to a battery and against short circuiting. To
protect the battery, the refrigerator switches off automatically if the voltage is
insufficient (see table below).
Cut-off voltage
Cut-in voltage
6.5
Connecting to a 230 V mains supply
Danger of fatal injuries!
d
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
Caution!
e
If you are operating your cooling device on board a boat with a
mains connection of 230 V from the land, you must install a residual
current circuit breaker between the 230 V mains supply and the
cooling device.
Get advice from a qualified specialist.
➤ To operate the refrigerator on the 230 V mains, use the WAECO MPS-35
rectifier.
7

Using the refrigerator

Note
I
Before starting your new refrigerator for the first time, you should
clean it inside and outside with a damp cloth for hygienic reasons
(please also refer to the chapter "Cleaning and maintenance" on
page 34).
Using the refrigerator
12 V
24 V
10.4 V
22.8 V
11.7 V
24.2 V