TRIMMER
FR.
Motor torque adjustment. The trimmer is set to provide sufficient thrust to work the gate
without exceeding the limits established by current standards (EN 12453). Turning
the trimmer clockwise (+) increases the motor torque, turning it anticlockwise
(-) reduces it.
RALL.
Deceleration adjustment: from 0 to 150 cm before the limit switch;
Note: the automation must perform a complete opening and closing manoeuvre
before setting the deceleration.
T.C.A.
Automatic closing time adjustment from 5 to 120 seconds.
Dip switch
1 on: after opening, the gate automatically closes when the delay set on the T.C.A. trimmer
expires.
off: automatic closing disabled.
2
on:
with automatic closing enabled, a sequence of open/close commands causes the gate
to OPENCLOSE-OPEN-CLOSE etc (see also dip switch 4).
off:
in the same conditions, the same command sequence causes the gate to OPEN-STOP-
CLOSESTOP-OPEN-STOP (step-by-step).
3 on: during opening, the photocell cuts in to stop the gate until the obstacle is removed. When
the obstacle is removed the gate resumes opening;
off: during opening, the photocell does not cut in.
4 on: NO-REVERSE function activated; the gate ignores the closure commands during
opening and reversal of movement occurs only during closure;
off: the open-close pushbutton reverses the direction of movement of the gate even while it
is opening.
5 on: the pre-flashing function enabled.
off: the pre-flashing function disabled.
6 on: the "photocell test" function is enabled;
off: the "photocell test" function is disabled. N.B.: to be used when the photocells are not
used.
7 - 8
2nd RADIO CHANNEL operation (terminals no. 18 - 19)
Dip 7 Dip 8 Function
OFF
OFF
OFF
ON
ON
OFF
ON
ON
9 on: the deceleration function is on and can be adjusted by means of the RALL trimmer;
off: the deceleration function is off;
10 on: left-hand leaf opening function;
off: right-hand leaf opening function;
11 on: ENCODER enabled: encoder obstacle detection function activated (use the trimmer FR
to adjust the sensitivity to obstacles);
off: ENCODER disabled;
12 on: RESISTIVE SENSITIVE EDGE (terminal no. 11);
off: FIXED EDGE (NC contact – terminal no. 11).
Gate contact open: The contact activates on opening the gate and
remains active during the open time, during the TCA and during reclosure.
It deactivates once the gate has completed its closure movement.
Bistable function active: the radio control impulse causes the contact to
activate and remain active until the subsequent impulse.
Monostable function active for 2 sec.: the radio control impulse causes
the contact to activate and remain active for 2 sec.
Monostable function active for 180 sec.: the radio control impulse causes
the contact to activate and remain active for 180 sec.
K580M
LOGIC ADJUSTMENTS
13