tau K580M Notice D'utilisation page 12

Carte de commande pour t-ones et t-ones (230 vac)
Masquer les pouces Voir aussi pour K580M:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1 - 2 - 3
(Power supply) POWER input 230 Vac 50Hz (115 Vac 60 Hz). 1= NEUTRAL 2=
EARTH 3= PHASE;
4 - 5
(Flashing light) FLASHING LIGHT output 230 Vac 50 W max. The signal is already
modulated for direct use. The flashing frequency during closing is double. 4= 230
Vac, 5= 0 Vac;
6 - 9
(Open/Close) OPEN/CLOSE pushbutton input (Normally Open contact);
7 - 9
(Pedestrian) PEDESTRIAN pushbutton input (Normally Open contact);
8 - 9
(Stop) STOP pushbutton input (Normally Closed contact);
10 - 11
(Fixed safety edge) SENSITIVE EDGE input (resistive sensitive edge or fixed
safety edge); Works only when the gate is opening; temporarily stops the gate
and partially closes it by about 20 cm in order to allow the obstacle to be removed.
(10=Common);
N.B.
If a resistive sensitive edge is connected, set dip-switch no. 12 to ON;
If a fixed safety edge with NC contact is connected, set dip-switch no. 12 to OFF;
10 - 12
(Photocell) input for PHOTOCELLS OR SAFETY DEVICES active during closure
(Normally Closed contact); They stop the gate during closing and totally reopen it;
they temporarily stop the gate during opening in order to allow the obstacle to be
removed (if dip switch n° 3 set to ON), (10= Common).
safety device, connect all the NC contacts IN SERIES.
N.B.
The photocell transmitter must always be supplied by terminals no. 13 - 15, since
the safety system test (phototest) is carried out on it. To override the testing of the
safety system, or when the photocells are not used, set dip-switch no. 6 to OFF. If
the phototest is not successful, the control unit will not operate.
13 - 14
(Photocell RX - 24 Vac) 24 Vac 10 W output to POWER THE RXs AND ANY OTHER
TXs OF PHOTOCELLS THAT ARE PRESENT, EXTERNAL RECEIVERS, etc.;
connect a max. of 3 pair of photocells. 13= 0 Vac, 14= 24 Vac;
13 - 15
(Photocell TX) 24 Vac 10 W POWER output for PHOTOCELL TX (only the one that
performs the Phototest) max. no. 1 photocell transmitter. 13= 0 Vac, 15= 24 Vac;
16 - 17
(Gate open warning light) GATE OPEN LED output 24 Vac - max. 3 W; during
opening of the gate the warning light flashes slowly, when the gate is open it remains
steadily illuminated and during closure it flashes twice as fast. 16= 0 Vac, 17= 24
Vac;
18 - 19
(2nd radio channel) 2nd RADIO CHANNEL output (its operation depends on dip-
switches nos. 7 - 8) to be used for opening/closing another gate, for controlling garden
lights or for the "ZONE LIGHTING" function;
20 - 21
(Antenna) 433,92 MHz built-in RX antenna input; 20= EARTH, 21= SIGNAL;
M1
quick coupling for LIMIT SWITCH connection (Normally Closed contacts). Orange=
ClosureLimitSwitch (CLS), red= OpeningLimitSwitch (OLS), grey= Common (COM);
M2
quick coupling for ENCODER connection. Blue= 0 Vdc (GND), brown= 5 Vdc (+5V),
white= ENCODER SIGNAL (ENC);
FS1 - FS2
faston for motor start-up CAPACITOR connection;
M3
quick coupling for 230 Vac single-phase MOTOR connection common= BLUE
(M-COM); closure= BROWN (M-CL); opening= BLACK (M-OP).
12
TERMINAL BOARD CONNECTIONS
K580M
If there is more than one

Publicité

Table des Matières
loading

Table des Matières