4.6 To depressurise tank, open the ball-shut-off valve and let air suck. Then take pump (P) out of
tank and dispose liquid properly .
5 . Maintenance and Cleaning
5.1 The tank is not determined to store the liquids. After every use tank has to be emptied. In case
other liquids than oil are used, tank has to be cleaned (with water or an appropriate cleaning
agent.) after every usage. Disposal of the liquid and the liquid to be used to flash the tank has
to be determined in conjunction with the information given by the manufacturer of the liquid
which has been sucked. Please, make sure that also the liquid with which the unit is flashed
will not do any harm to the components of the equipment.
5.2 The life of the unit can be extended if the piston (M) is greased occasionally.
5.3 To disassemble the pump with the piston (M), pull the pump handle all the way out, make sure
that the guiding lever (F) is clicked into position and turn handle counterclockwise 1/8 of a turn.
6 . Troubleshooting
Fault
6.1 Pressure drop in the unit:
Either connection between vacuum meter and tank
between pump and tank or hose and tank is not sealed
properly.
6.2 Pump (P) does not develop depressurisation / pump
can be moved very easily:
* Ball-shut-off valve (K) is open
* Piston (M) is broken
* Suction (SV) is damaged
* Obstacle enables valve to be closed
6.3 Pump cylinder is pulled due to under-pressurisation
* Suction valve (SV) is glued
6.4 While pumping liquid is pulled out of the pump into the
filling funnel
* Tank is full
* Tank is not upright
* Pump sleeve (U) is missing
* Pump sleeve (U) is broken
CE Declaration of Conformity
according to EC Machinery Directive 2006/42/EC, Appendix II, No. 1A. We, MESTO Spritzenfabrik
Ernst Stockburger GmbH, Ludwigsburger Straße 71, D-71691 Freiberg declare under our sole
responsibility that the devices of the series 3253 in the version supplied comply with all relevant
provisions of the Directive 2006/42/EC. Furthermore, the device complies with the Directive
2014/68/EU for pressure equipment.
Mr. Rolf Rehkugler is authorized to compile the technical documentation.
Freiberg, 13.12.2016
Bernd Stockburger - Managing Director –
1117
AUS
USA
Original operating instructions
6
NZ
CDN
Solution:
Tighten connections , if necessary
replace seals on pump and vacuum
meter
Close shut-off-valve
Replace piston
Replace pump or suction valve
Clean valve
Clean valve or replace, or replace
pump
Empty tank
Put tank in upright position
Put pump cover over pump
Replace pump cover