Warning! This electric tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain
conditions. In order to prevent the risk of serious or
deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operat-
ing the electric tool.

6. Before operation

Installation (Fig. 1/2)
To attach the handle (1), remove both Phillips screws
M6x35 mm which are inserted. Place the handle (1) in
position and screw it tight. Attach all parts before pour-
ing in fuel or oil in order to prevent leaking of liquids.
Electrical safety
Electrical cables and attached devices must be de-
fect free. Never connect the generator to the mains
(power point). Keep the cables as short as possible.
Environmental protection
Dispense of polluted maintenance and operating ma-
terials in a suitable collection point.
Earthing (Fig. 1)
Earthing is needed to disperse static discharge. Connect
a cable from one side of the earthing connector (7) of the
generator and from the other side to an external ground.
ATTENTION! When being used for the first
time, motor oil (15 W-40, approx. 0.6 l) and petrol
(unleaded normal petrol) must be put in.
Check the fuel level and the oil, and if necessary
top them up.Make sure you have adequate ventila-
tion. Ensure that the spark cable is securely in the
spark plug. Unplug any electric device connected to
the generator.
Putting in oil (Fig. 5)
Put the generator with its front side down and un-
screw the oil filler plug (13). Pour in 0.25 litres of en-
gine oil (15 W-40).
Close the oil filler cap (13) and stand the generator
upright
Putting in fuel (Fig. 1/7)
Switch off the motor! Keep away from ignition sourc-
es! Always refuel in well-ventilated rooms or outside.
Open the fuel tank cap (2) and, using a filler pipe (not
included in delivery), pour in a maximum of 4.2 litres
of unleaded fuel into the fuel container. Ensure the
tank level is not exceeded and no fuel is spilled. Use
the fuel filter. Clean up spilled fuel immediately and
wait until the fuel fumes have evaporated (fire haz-
ard). Close the fuel tank cap (2).

7. Operating

Start the engine (Fig. 1/3/6 )
ATTENTION! When starting with the express start
you can injure your hand with the sudden kick back.
Wear protective gloves when starting.
1.
Open the petrol tap by turning the tap down-
wards.
2.
Put the on / off switch (6) to the on position.
3.
Turn the choke lever (9) to I I (in the left position).
4.
Start the engine with the express start (10) by
sharply pulling the handle. If the engine has not
started pull the handle again.
5.
Push the choke lever (9) back once the engine
has started (in the right position).
6.
Connect the device to the 230 V~ socket (8).
ATTENTION! This socket can be loaded continuous-
ly (S1) with 1000 W and short term (S2) for
a maximum of 5 seconds with 1200 W.
Note: Some electric devices (sabre saws, drills etc.)
can use more electricity when doing heavy duty
tasks.
Storing the engine (Fig. 1/6)
Before putting away, let the generator run without
load so that the device can „cool down".
Turn the on / off switch to the „OFF" position.
Close the petrol tap.
Overload protection 230 V~ socket
WARNING! This generator is fitted with an overload
protector.
This cuts off the sockets
Green operating bulb
Flashes 1 x per interval
Speed too low
Flashes 2 x per interval
Temperature too high
Flashes 3 x per interval
Overload protection
switches on
Flashes 4 x per interval
Short circuit
The socket (8) can be used again after the overload
protection has been triggered once the engine has
been switched off and restarted (See "Turning off en-
gine" and "Starting engine").
ATTENTION! If this happens reduce the amount of
electrical output which you are extracting from the
generator or remove defective devices which are at-
tached.
ATTENTION! Faulty overload switches
should only be replaced with identically
constructed overload switches with the
same performance data. Please use our
customer service department.
Cleaning, maintenance, storage,
transport and ordering
replacement parts
Before cleaning and maintenance work, turn off the
engine and pull the spark plug connector (15) out of
the spark plug (16) .
GB / 17