Engine displacement
Max. power (motor)
Fuel:
Tank capacity
Engine oil
Use at 2/3 engine load
Weight
Sound pressure level L
pA
Sound power level L
WA
Uncertainty K
Power factor cos ϕ
Performance class
Quality class
Spark plug
Operating mode S1 (long use)
The machine can be used continuously with the
indicated power.
Operating mode S2 (Short term use)
The machine can be used in the short term with the
indicated power (5 s)
Acceptable ambient temperature:
-10 to +40 °C
Height: 1000 m above NN
rel. air humidity: 90 % (not condensed)
5. Safety instructions
1.
No modifications are allowed to be made to the
generator
2.
The speed preset by the manufacturer may not
be changed. The generator or connected devic-
es could be damaged.
3.
Risk of poisoning! Fumes, fuels and lubricants
are toxic. Do not breath in the fumes.
4.
Fire risk! Petrol and petrol fumes are highly
flammable and explosive.
5.
Do not use the generator in non ventilated rooms
or in highly flammable areas. When the genera-
tor should be used in a well ventilated room, the
fumes must be channeled outside through a ex-
haust hose.
16 / GB
53,5 cm³
2,1 kW/2,85 PS
unleaded fuel
This device may
not be operated
with E10 petrol
4,2 l
0,25 l
(15W-40)
approx.0,88 l/h
12,8 kg
74 dB(A)
95 dB(A)
1,07 dB (A)
1
G1
B
A7RTC
6.
Even when using an exhaust hose, toxic gas can
still escape. Due to the risk of fire, the exhaust
hose should never be aimed at combustible ma-
terial.
7.
Never use the generator in rooms with highly
flammable materials.
8.
Hot surface! Risk of burning, do not touch the
exhaust system and engine unit.
9.
Do not touch any of the mechanically moving or
hot parts. Do not remove any of the protective
caps.
10. Protective equipment! Use suitable ear protec-
tion when near the device.
11. Only original parts should be used for mainte-
nance and accessories.
12. Repair and maintenance work must only be per-
formed by authorised qualified personnel.
13. Protect yourself from electric shocks.
14. Never touch the generator with wet hands
15. Only use outside with a extension cable which
is suitable for that and is appropriately marked
(H07RN).
16. When using an extension cable, the total length
should not exceed 50 m for 1.5 mm², 100 m for
2.5 mm².
17. Do not use the generator in the rain or snow.
18. Always turn off the engine when transporting or
refuelling.
19. Ensure that no fuel is spilt on the engine or ex-
haust when refuelling.
20. Do not refuel or empty near naked lights or
flames or flying sparks. Do not smoke!
21. Put the generator on a secure and level place.
Turning, tipping or changing its position during
operation is forbidden.
22. Install the generator at least 1 m away from the
walls or attached devices.
23. Keep the generator away from children.
24. Emission levels are represented in the technical
data under the stated values for sound power
level (LWA) and sound pressure level (LpA) and
are not compulsory definite working levels.Be-
cause there is a connection between emission
levels and immission levels, this can not reliably
used to determine the potentially necessary ad-
ditional precautions. Influencing factors on the
workforce's current immission level includes the
properties of the work area, other noise sources,
air borne sound, etc. such as e.g. the number of
machines and other neighbouring processes and
intervals, to which the user is exposed. Also the
admissible immission levels can vary from coun-
try to country. However, this information gives
the user of the machine the opportunity to have a
better estimation of the risks and dangers. Occa-
sionally acoustic measurements should be take
after installation in order to determine the sound
pressure level.
ATTENTION: Only use unleaded normal petrol as
fuel.