Table 5-1. Troubleshooting Guidelines
SYMPTOM
POSSIBLE CAUSE
Charger does not
Loose power cord
operate at all
Blown fuse
LED fails to light
Bad battery pack
on one output
Failed output cord
Battery pack
Failed batteries
will not operate
for its specified
duration
In all of the above cases, and for any other failures, the Omega Five Unit Charger may be
returned to MSA for repair
Table 5-2. Replaceable Parts List
ITEM
Linecord, NEMA 5-15P 115-V operation
Fuse, 5 x 20 mm, 3/8A, SB 230-V operation
Fuse, 5 x 20 mm, 3/4 A. SB 115-V operation
Fuse, 3AG, 3/8A, SB, 230-V operation
Fuse, 3Ag, 3/4A, SB, 115-V operation
*For use on models manufactured with 8-inch wide enclosures (HO2 or later Datecodes)
CORRECTIVE ACTION
Check connections at mains and at rear panel
Replace fuse; verify mains voltage selection
Try another pack or move the pack to another
output; replace any bad battery pack
Replace the cord
Replace the pack
PART NO.
634073
*10043121
*10043120
627644
628014