Ultraheat Electric heater
Important operating notes
Repairs may only be carried out by an expert.
Due to the design, the heater front case will
become hot during operation. The operator is
obliged to ensure that due care is taken to pro-
tect third parties (small children in particular).
The heater's hot air outlet should under no circumstances be
blocked. Never hang clothes or similar in front of or on top
of the heater to dry. This could cause serious damage to the
heater as a result of overheating. Do not place inflammable
materials near the heater! Please observe these instructions
for your own safety.
When operating a brand-new heater for the first time (or after
it has been idle for a lengthy period) you may temporarily no-
tice a slight smoke and smell. We advise running the heater at
full power and thoroughly ventilating the room.
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
– modifications to the unit (including accessories),
– failure to use original Truma parts as
replacement parts and accessories,
– failure to follow the installation and operating instructions.
Furthermore, the approval for operating the appliance will
become invalid and in some countries also the approval for
operating the vehicle.
Caution
espite careful manufacture, the heating system may
contain sharp-edged components, and protective
gloves should always be worn when carrying out any
maintenance or cleaning work!
4
3
4
1
2
Short description
Truma Ultraheat is an additional 230 V electric heater for the
LPG heater models Trumatic S 3002 (P), Trumatic S 5002
and Truma S 55 T.
Heater operation is basically possible with gas only, electricity
only or simultaneously with electricity and gas.
When using simultaneously the electrical unit will switch itself
off before overheating occurs as a result of the stronger gas
burner.
When using electrical only we recommend to set the fan
control on position 3 (manual or auto), remembering to set the
output level to 2000 W (ensure that the fuse protection for the
power supply of the camp site is sufficient).
If more than 2000 W are required (heating up / cold tempera-
tures) you must refer back using gas operation as the 230 V
electrical operation is a secondary heater only.
The heater operation is regardless of the operating mode (gas
oder electricity) also possible without the Trumavent fan.
To ensure an even and rapid warm air distribution as well
as lower surface temperatures on the heating unit, we do
recommend that you always operate the heater with a
running Trumavent warm air system.
If your Ultraheat is fitted with a remote sensor (accessory), do
not position it near any heat source (oven, lights, opposite of
blown air outlets etc.) or near a confined area where heat can
accumulate (under a shelf, near corners, behind curtains).
Installation example
1 Liquid gas heater Trumatic S
2 Truma Ultraheat
3 Control panel with thermostat
4 Trumavent fan and comfort
kit with Airmix (for warm air
distribution – optional), not for
Truma S 55 T
Accessories
Extension cable for the control
panel, length 5 m
(part no. 34300-01)
– not illustrated –
Remote sensor FFC 2, monitors
the room temperature, regardless
to the position of the control panel,
comes with a 4 m connecting
cable (part no. 34201-01).