EINHELL STE 5500 Mode D'emploi page 8

Masquer les pouces Voir aussi pour STE 5500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Anleitung STE 5500 SPK 1
GB
Max. power:
9,55 KW / 13 CV
Fuel:
normal unleaded petrol
Tank capacity:
Quantity of oil
Weight:
LWA sound power level:
Sound pressure level LWM:
Spark plug:
NGK BPR5ES
12. Changing and checking the oil level
The engine oil is best changed when the engine is at
working temperature.
Use only engine oil (15W40).
Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
Open the oil filler plug.
Open the oil drain plug and let the hot engine oil
drain out.
After the old oil has drained out, close the oil drain
plug and place the generator on a level surface
again
Fill in engine oil up to the top mark on the oil dip
stick
Important: Do not screw in the oil dip stick – only
14. Troubleshooting
Cause
Fault
Automatic oil cut-out has not res-
Engine does not start
ponded
No fuel
Controller or capacitor defective
Generator has too little or no
Overcurrent circuit-breaker has
voltage
triggered
Air filter dirty
8
27.08.2004
10:58 Uhr
insert it.
Dispose of the old oil properly.
13. Cleaning the air filter
25,0 l
1,1 l
Remove the cover from the air filter.
88 kg
Now you can remove the filter elements.
97 dB(A)
Do not use abrasive cleaning agents or petrol to
92 dB(A)
clean the elements.
Clean the elements by tapping on a flat surface.
Remedy
Check the oil level, top up with
engine oil
Refuel
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter
Seite 8