Storage Space - Electrolux thermaline S90 Instructions D'installation Et D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.1
GAS BURNER
So far as is necessary, the pilot burner and main burner are
cleaned by after-sales service.
3.2
FLAME
In a visual check, the flames must be dark blue without any
upper yellow or orange tips; they must be stable and soot-free
and adhere firmly to the outlets.
If there is a lack of primary air, the flame has yellow streaks
and tips; if there is too much primary air, the flame is short,
transparent and tends to lift off the burner.
When the flame is correctly adjusted, it must not lift off or back-
fire when the burner is cold as well as warm.
The flame will backfire into the inside of the burner when the
speed of the gas-air mixture through the burner outlets is too
low, particularly when the air passages are dirty.
The different ignition processes must also take place without
any delays. This concerns: ignition, arc-through and. extending
the flame over the whole burner area.
If the flame fails to meet all the requirements, cleaning or
maintenance is necessary.
4.
MALFUNCTION
The burners are not accessible to operating personnel.
Therefore, in the case of a fault, specialist staff must be reque-
sted.
Malfunction
Possible cause
Flame smokes.
• Gas mix too rich.
• Partially blocked burner
gaps.
Long yellow flame tips.
• Mixing tube narrowed by
dirt.
Flame lifts off.
• Exit velocity too high due
to blocked burner gaps.
• Deformed burner cover.
• Pressure regulator on
gas cylinder not opera-
ting correctly.
Flame flashes back.
• Mixture too lean.
• Insufficient exit velocity
at burner gaps.
• Soiled airways
• Blocked nozzle.
• Deformed or burnt-out
burner cover
No flame or flame too
• Blocked nozzle or mixer
small.
tube.
• Blocked gas tap.
• No gas.
• Insufficient gas pres-
sure.
No flame at low setting.
• Blocked low setting
nozzle.
Pilot burner
No flame.
• Blocked burner gaps.
• Blocked nozzle.
Flame goes out after con-
• Thermo-element insuf-
trol valve release.
ficiently heated (dirty?)
• Defective thermo-ele-
ment
Flame too small or too
• Primary air ratio adju-
large.
sted.
• Nozzle blocked.
Page 10
OPERATING INSTRUCTIONS
5.
The storage space (Fig.10) is incorporated into the base unit.
Recommended accessories:
1 Shelf holder
2 Shelves
Fig.10 Storage space
Remedy
- Inform Customer Ser-
vice.
- Inform Customer Ser-
vice.
- Inform Customer Ser-
vice.
- Inform Customer Ser-
vice.
- Inform Customer Ser-
vice.
- Check gas tap setting.
- Inform Customer Ser-
vice.
- Clean pilot burner cap.
- Inform Customer Ser-
vice.
- Inform Customer Ser-
vice.

STORAGE SPACE

- Shelf holder (1) 2 off.
- Shelves (2) 1 off.
62.9534.01_UL