Gas Cylinder - Broil King BARON 440 PRO Mode D'emploi

Masquer les pouces Voir aussi pour BARON 440 PRO:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LP GAS CYLINDER
The standard for outdoor gas appliances, ANSI Z21.58/
CAN/CGA-1.6, requires that LP gas cylinders used with LP gas
appliances be equipped with both
An Overfill Prevention Device (OPD)
A QCC®-1 Quick Closing Coupling system
OVERFILL PREVENTION DEVICE
The O P D is designed to reduce the potential of over filling propane
cylinders, thus reducing the possibility of relief valve discharges of
raw propane. The OPD causes a slower purge/fill operation.
QCC®-1 QUICK CLOSING COUPLING
The QCC®-1 system incorporates safety features required by the
American National Standards Institute (ANSI) and the Canadian
Standards Association (CSA).
Gas will not flow until a positive connection has been made
A thermal element will shut off the flow of gas between 240° and
300° F
When activated, a Flow Limiting Device will limit the flow of gas
to 10 cubic feet / hour
The LP gas cylinder is not included with the Gas Grill.
Be sure to use an LP gas cylinder equipped with the OPD and the
QCC® valve.
IDENTIFICATION
The QCC®-1 valve is recognized by the external threads on the inlet
port of the LP gas cylinder valve.
The OPD hand wheel has been standardized to the shape shown.
QCC® /OPD equipped LP gas cylinders are available from your Gas
Grill Dealer.
NOTE: Any attempt to connect the regulator, by use of adapters
or any other means, to any other valve could result in damage,
fire or injury and may negate the important safety features in
the QCC®-1 system.
SPECIFICATION
1
.
All LP gas cylinders used with this appliance must be
constructed and marked in accordance with the Specifications
for LP gas cylinders of the U.S. Department of Transportation
(D.O.T.) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres and Tubes for Transportation of Dangerous
Goods ; and Commission, as applicable.
2.
The LP gas cylinder used for this appliance must not have a
capacity exceeding 20 lb. (9 kg). Approximately 18" (46cm) high
and 12" (31cm) diameter.
3.
All LP gas cylinders used with this appliance should be
inspected at every filling and re qualified by a licensed service
outlet at the expiry date (10 years), in accordance with the DOT
(USA) and Canadian Transport Commission (Canada) codes for
LP Gas Cylinders.
4.
All LP gas cylinders used with this appliance must be provided
with a shutoff valve terminating in a cylinder valve outlet No.
510, specified in the Standard for Compressed Gas Cylinder
Valve Outlet and Inlet Connection (USA) ANSI/CGA-V-1-1977
(Canada) CSA B96.
5.
The LP gas cylinder supply system must be arranged for vapor
withdrawal.
6.
The LP gas cylinder must include a collar to protect the
cylinder valve.
7.
The LP gas cylinder must be installed as per assembly
instructions.
8.
Never fill the LP gas cylinder beyond 80% full. A fire causing
death or serious injury may occur.
9.
The LP gas cylinder valve must include a safety relief device
having direct communication with the vapor space of the
cylinder.
3

Publicité

Table des Matières
loading

Table des Matières