GB
6.2 - PowerBox™ Comfort 24l Additional cleaning
notice
You can remove the textile liner as shown drawing H1.
Never put in the washing machine.
First clean outside and inside with damp cloth. Please ensure
that you correctly place the liner back under the plastic box
in order to keep original performance.We advise you to use
a ruler to put the liner back.( Drawing H2)

7.TROUBLESHOOTING GUIDE

The PowerBox™ thermo-electric cooler is guaranteed for 2
years. If you have a problem with your thermo-electric cooler,
we advise you to read the following with care.
7.1 - Problem with connection
Your cooler and the outside fan are not running
(Green LED off).
• Check the car lighter socket. In most vehicles, the ignition
must be turned on for the lighter to work. If the ignition is
turned on but the cooler is not operating. Remove the plug
from the socket immediately, and make the following checks:
- Cigarette lighter socket: when the cigarette lighter is used
frequently, it can be soiled by tobacco, causing a bad elec-
tric contact. Clean it with a non-metallic brush.
- If the cooler plug heats abnormally in the cigarette lighter,
clean the socket or check to make sure the plug is assem-
bled correctly.
- Connector fuse: the connector of your 12Vdc power
supply cable is protected by a fuse (7A). Check that the
fuse has not blown by unscrewing the cooler 12Vdc
connector plug. (drawing I)
7.2 - Problem with cooling
• The green LED is working, but the cooler does not cool
correctly and the outside fan is not running.The fan motor
is probably defective, contact After Sales Service.
• The cooler does not cool correctly and the outside fan is
running. Open the lid to check the operation of the inside fan:
- If the inside fan is not running, the fan motor is probably
defective, Contact After Sales Service.
- If the inside fan is running, the Peltier System is probably
defective, Contact After Sales Service.
8. GUARANTEE (drawing J)
The PowerBox™ thermo-electric cooler is guaranteed
for 2 years. Our general guarantee conditions cover
the cooler. For repair, return the unit to the point of purchase
or to the After Sales Service, with the following information:
1. A copy of the receipt - with the date of purchase.
2.The reason for the claim / A description of the fault
concerned.
This does not affect your statutory rights.
Please only return the Thermo-electric lid.
15/09/06
11:32
Page 5

TECHNICAL CHARACTERISTICS

Capacity
Voltage
Intensity
Power Input
Weight
Heating Capacity
Battery Control
Insulation without
CFC and HCFC
Lid insulation
Box insulation
Refrigerating Unit:
thermo-electric system
Extra Passive lid
Dimensions (cm) (drawing K)
A
B
C
D
E
F
Capacity
Voltage
Intensity
Power Input
Weight
Heating Capacity
Battery Control
Insulation without
CFC and HCFC
Lid insulation
Box insulation
Refrigerating Unit:
thermo-electric system
Extra Passive lid
Dimensions (cm) (drawing K)
A
B
C
D
E
F
United Kingdom, Ireland • Consumer Service • Coleman
Gordano Gate Portishead • BRISTOL BS20 7GG • ENGLAND
Phone: 0044 1275 845 024 - Fax: 0044 1275 849 255
E-mail: customerservices@colemanuk.co.uk
PowerBox™
24l Classic-A
ref. 068679
24l
12Vdc
4.5A
54W
3.5kg
G
EPS foam
PU foam
G
34.5
22
32
27.5
38.5
42.5
PowerBox™
PowerBox™
28l Classic-AP
24l Comfort-A
ref. 069182
ref. 068678
28l
24l
12Vdc
12Vdc
4.5A
4.5A
54W
54W
4.3kg
3.3kg
G
G
EPS foam
EPS foam
PU
EPE closed
foam
cells foam
G
G
G
34.5
34.5
22
22
38
32
27.5
27.5
38.5
38.5
50
42.5
PowerBox™
28l Classic -A
ref. 069180
28l
12Vdc
4.5A
54W
3.8kg
G
EPS foam
PU foam
G
34.5
22
38
27.5
38.5
50
PowerBox™
28l Deluxe-B
ref. 069181
28l
12Vdc
4.5A
54W
4.3kg
65°C
G
G
EPS foam
PU
foam
G
G
34.5
22
38
27.5
38.5
50
®
Uk Plc
5

Publicité

Table des Matières
loading

Table des Matières