Problem
The appliance does not operate.
Abnormal noise can be heard during
operation.
When opening the door, the rubber seal
pops out.
Water accumulates on the interior floor.
The temperature inside the cabinet
compartment is too cold.
The temperature inside the cabinet
compartment is not low enough.
Condensation is accumulating on the
exterior housing.
Possible cause and solution
- Unit is not connected to the mains
power.
- A circuit breaker or fuse has been
triggered.
Either the unit has been improperly set up
(e.g. on an uneven floor) or there is contact
between the rear-mounted cooling circuit
and the power cord, the wall or other
object or surface. Verify that all
installation instructions in this manual
have been correctly complied with.
The seal must be re-fitted properly, by
pressing in the inner part of the seal. If the
seal shows signs of a greasy residue, the
seal and the door must be properly cleaned
with water and a mild detergent, and then
thoroughly dried before the seal is
replaced in the door.
The melt-water drain system is blocked.
Remove blockage and clean drain system.
Check the temperature setting: it may be
too low.
- Check the temperature setting.
- The ambient temperature requires a
higher temperature setting.
- The door has been opened too often,
or was left open.
- The door is not closed properly.
- The rubber seals in the door are not
positioned correctly.
- Insufficient space between the rear of
the unit and the wall.
- A high level of humidity in the ambient
air causes condensation. It can be
simply wiped off.