Calibrating the System----cont.
Before Calibrating
Make sure that your display is set to at least 16-bit color.
Make sure your display is set to "Professional" mode. To do this, press the "Picture Effect" button on the front of your GDM-
C520 display until the on-screen display shows "Professional".
Warm the display up by leaving the display turned on and displaying a relatively bright screen (over 50% white) for at least
an hour before calibration.
Make sure that the Artisan™ Sensor is connected to one of your computer's USB ports.
Make sure that the display and sensor are clean before beginning calibration. If necessary, the suction cups can be cleaned
with a damp, lint-free cloth. The display screen should be cleaned according to the instructions titled "Notes On Cleaning
the Screen's Surface" on page 3 of the display manual.
Turn the light in the room down to approximately 16 lux. The calibration process works best when there is little light in the
room.
When you first start the Artisan™ Software, you will see the following screen:
1
Select the preset colorspace to which you want your display to be calibrated by clicking on the "Target Colorspace"
drop-down menu. You can calibrate your display to any one of the following standard target colorspaces:
Name
CRS Print RGB-D50
CRS Print RGB-D65
CRS Web RGB (sRGB)
2
Click on the desired target colorspace.
3
Click on the "Calibrate" button to continue.
x
y
value
value
.3457
.3587
.3128
.3292
.3128
.3292
19
Y value
Y value
(White)
(Black)
85.0 cd/m^2
0.28 cd/m^2
85.0 cd/m^2
0.28 cd/m^2
85.0 cd/m^2
0.28 cd/m^2
TRC
Gamma 1.80
Gamma 1.80
Gamma 2.20
modified per ITU
initial slope