Lubrication
Lubricate the meter with the on the meter indicated oil according Table 5.
If there is no lubricating oil indicated on the meter, then lubricate with oil
manufactured by Klüber, type Isoflex PDP38.
First open the cover of the oil reservoir.
Fill the reservoir with the supplied oil.
The oil quantity is enough when the oil level is visible in the strainer.
Operate the oil pump as instructed in Table 5
Close the oil reservoir.
Under normal conditions 2–3 lubrications a year are sufficient.
Sizes:
DN 50
DN 80
DN 100
DN 150
DN 200
DN 250
DN 300
DN 400
DN 500
DN 600
Table 5 Lubrication dosage
Automatic Lubrication System
For remote installed Turbine meters an automatic lubrication system is
developed for convenient lubrication.
Contact Elster-Instromet for more information.