SC ISTICK PICO S – ERROR MESSAGES & PROTECTIONS
Over 10 Sec� Protection
If you hold the Fire button down for more than 10 seconds, the device will turn off automatically� The display will
show "Over 10s Protection"�
Atomizer low Alarm
If the resistance of the coil drops below 0�05 ohm in VW or Bypass mode, or below 0�05 ohm in TC mode,
"Atomizer Low" will show on the display�
Excess Voltage Protection & no Atomizer Head detected
If there is excess voltage on the vaporizer, the display will show "Atomizer Short"�
"No Atomizer Found" will show on the display if no atomizer is connected�
Low Voltage Protection
If the battery voltage drops below 3�1 volts, the display will first show "Battery Low", then "Lock"�
Charge the battery to unlock the device�