Télécharger Imprimer la page

LEGRAND 0 570 10 Manuel D'installation page 44

Publicité

Les langues disponibles

Les langues disponibles

11. Charger Control Application
The charging station is ready to use after the installation is completed.
You can control the charging station and change settings with the Charger Control Application.
In this chapter is described the settings, which are only allowed for qualified professionals.
For additional instructions please see the User Guide.
Note! Do not change the settings while charging is in progress.
11.1. Pro settings in the Charger Control Application
WARNING
Danger of electric shock! Risk of fire!
Settings described in this chapter must only be done by a
qualified professional.
Open the Pro menu
Open the Charger Control on your mobile device.
Go to "Settings".
Press PRO on the top right corner.
Available settings depend on the installed charging system.
11.2. Charger Settings
In this menu you can find settings related to the charging station.
11.2.1. Technical max. charging current
Maximum current that the electrical supply of the property can provide to the charging station.
When you define the technical maximum current, take into account the main fuse size and the possible
total energy consumption of the property. A safety limit prevents unnecessary triggering of the fuse and
protective devices.
11.2.2. Overcurrent limit
Certain car models tend to take more charging current than set as the charging station's maximum charg-
ing current.
In case an overcurrent of 10% lasts longer than 2 minutes, it results an error state. If the overcurrent is 16%
it results an error state immediately.
You can prevent unnecessary error states by setting an overcurrent limit.
If the charging current is lower than 10A, you can set the overcurrent limit up to 30%.
44 / 68
LERAK131B_20221004

Publicité

loading

Ce manuel est également adapté pour:

0 570 17