Télécharger Imprimer la page

LEGRAND 0 570 10 Manuel D'installation page 34

Publicité

Les langues disponibles

Les langues disponibles

0 570 14 / 0 570 16:
Install a residual current device (RCD type F or A, 30mA) and a cir-
cuit breaker (MCB max. 16A or max. 32A depending on charging
station model) to the supply line. In addition obey local regula-
tions for the power supply line.
Do not connect these charging station models to an IT network.
0 570 11 / 0 570 13:
A combined device with residual current circuit breaker and over
current protection (RCBO) is integrated.
A label set of RCBO testing instructions is included in the delivery.
Attach a language specific label on the installation box hatch.
Do not connect these charging station models to an IT network.
34 / 68
LERAK131B_20221004
TN / TT network
L1 L2 L3
L1
N
PE
PE
L1 L2 L3 N
Supply
Cu 2.5 - 10 mm²
TN / TT network
L
N
PE
QF1
L
N
PE
L
N
Supply
Cu 2.5 - 10 mm²

Publicité

loading

Ce manuel est également adapté pour:

0 570 17