English
Thank you for placing your trust in our company by purcha-
sing the Weller Zero Smog 4V volume fume extraction unit.
Production was based on stringent quality requirements
which guarantee the perfect operation of the device.

1. Caution!

Please read these Operating Instructions and the attached
safety information carefully prior to initial operation. Failure
to observe the safety regulations results in a risk to life and
limb.
The manufacturer shall not be liable for damage resulting
from misuse of the machine or unauthorised alterations.
1.1 Applied directives
The Weller Zero Smog 4V volume fume extraction system
extraction unit corresponds to the EC Declaration of
Conformity in accordance with the basic safety requirements
of Directives 2004/108/EC and 2006/95/EC.
1.2 Valid documents
- Operating Instructions of the Zero Smog 4V solder fume
extraction unit
- Accompanying safety instruction booklet

2. Description

The WELLER Zero Smog 4V solder fume extraction unit is
equipped with a high-performance, maintenance-free turbi-
ne and, therefore, is ideally suited to industrial continuous
duty. Digital electronics make for easy and convenient
system operation. The unit is designed for use as a surface
extraction unit and is not suitable for extracting fumes
directly from the soldering gun. Turbine speed, i.e. delivery
rate, is continuously variable up to max. 230 m
hose connections are available for connecting the pipe
system. This means that the pipe system can be customized
for individual requirements. The installed 3-stage filter (fine
dust filter, suspended matter filter and broadband gas filter)
is configured as standard for the extraction of solder fumes.
Thanks to the use of class E 12 (formerly H13) type-appro-
ved suspended matter filters, the as-delivered filter set
achieves a separation efficiency of 99.95 % according to EN
1822, based on a particle size of 0.12 μm. These figures can
only be achieved by using OEM parts.
The WELLER Zero Smog 4V solder fume extraction unit can
be connected using a flexible suction hose or connected
directly to the vacuum tube system (60 mm). For this purpo-
se, the corresponding screw cap must be removed from the
filter housing (1). Fit the 60 mm hose connection (3) to the
filter housing (2) using 3 fastening screws. A maximum of 4
hose connections can be fitted. Unused vacuum connections
must be sealed. A wide range of accessories from the Easy
Klick 60 line are available for installation of the extractor-
17
arms. (Refer to Weller catalogue, www.weller-tools.com,
Configurator).
Filter display (15)
When the filter is used up, an audible signal sounds
once an hour
every half hour after 36 hours
every 10 min after 54 hours
continuously after 72 hours.
The suspended matter filter and the broadband gas filter are
complementary to one another and can be replaced together
as a compact filter. The fine dust filter (16) (filter mat) is the
preliminary stage of the compact filter (17) and therefore
must be replaced more frequently. It is sufficient to replace
the prefilter mat if the red LED (15) does not come on after
restarting the unit.
RS232 port
All system functions can be operated and remotely monito-
red via the RS232 port (14).
USB port
The USB port (13) can be used to load firmware updates, run
3
/h. Up to 4
efficiency tests and log data.
Do not leave the USB medium inserted for longer than
2 minutes. After this time expires, the USB module
will switch off automatically.
Technical data
Dimensions L x W x H:
Weight:
Voltage:
Electrical power rating:
Maximum vacuum:
Maximum quantity supplied: 230 m
Pre filter:
Combined filter: Stage 2; 3 Combined E12 high efficiency
The degree of clogging of the filter is
determined by differential pressure
measurement. The filter display (15)
indicates the current filter status
Red = filter full
Yellow = filter status > 80%
Green = filter status < 80%.
320 mm x 320 mm x 395 mm
19 Kg
230 V/50 Hz (120 V/60 Hz)
275 VA
2,700 Pa
3
/h
Stage 1
pre filter mat class F7
submicron filter (99.95 %
particle separation upto
0.12 μm) and wide band gas
filter (50 % activated carbon,
50 % Puratex)

Publicité