STEP 7
Use appropriate copper wire with listed pressure
terminal connectors, (ring and fork types), on
the end of the conductor before attaching to the
terminal blocks. Keep enough length of wire to
facilitate installation. Connect each conductor to
the correct terminal input block connector in the
compartment and torque to 19 lb·in (2.2 N·m)
Model
Copper wire type
EVR40-B25
No. 6 AWG, 90˚C
EVR30-B18
No. 8 AWG, 75˚C or 90˚C
EVR30-R25
No. 8 AWG, 75˚C or 90˚C
NOTE: Choose appropriate conduit in accordance
with all applicable state, local and national electrical
codes and standards.
STEP 9
Replace the front cover by aligning the hinge on
the top. Secure the front cover by the bottom
screw, torque to 10.4 lb·in (1.2 N·m).
5
STEP 8
Replace the compartment cover and torque to
8.7 lb·in (1.0 N·m).
STEP 10
Ensure that the Charge Cord is positioned so it
will not be stepped on, tripped over, or otherwise
subjected to damage or stress. Always stow the
EVSE Charge Cord safely after each use.
www.leviton.com/evrgreen
Optional Cable
Hanger Bracket
(Not supplied)