Appendix A1 - A3
A1 Synchronization
Following a malfunction or after exchanging an
electronic part a synchronization procedure must
be carried out. The procedure is:
If necessary turn the remote control
OFF = push
System ON = turn isolation switch on
E-box reset-button = push and hold !
Handset turn ON = Double click
LED remote control
LED Basic Station
Handset turn OFF = push
LED remote control
LED Basic Station
Release reset-button
The synchronization is completed.
Attention! Avoid pauses of more than 2
seconds
during
otherwise the synchronisation has to be
restarted.
After approx. 20 seconds, the remote control will
be switched-off automatically, if there were no
entries!
GB8
On
Off
the
synchronization,
A2 Reset
The reset process is only required if the LED of
the Basic Station is eluminated. This is an error
signal (for example overload) - the LED is usually
off.
When resetting the overload protection reverts to
its normal position.
Turn ON handset = Double click
Basic Station reset-button = push
LED Basic Station
Turn OFF handset = single click
The reset process is complete.
Attention! If the LED does not turn off after
repeating reset procedure for several times,
please contact your dealer.
A3 Maintenance
A) At least once a year please have your
MoveControl
maintained
inspected as described below:
- Cleaning of the complete drive unit.
- Application of suitable lubricant to all moving
parts (e.g. silicon spray).
- Check of the distance between the drive
rollers and the tyres as well as a checking the
tyre pressure.
- Visual inspection for damage of the cables
and the electrical connections.
- Check battery voltage.
- The threads at the spindles are regularly, at
least once a year before putting into operation,
treat with a suitable lubricant and checked for
easy going.
B) Before moving please check if the moving
drive is free of dirt, sand and debris.
C) In case of failures or problems please contact
your supplier.
Off
and
visually