How do I locate faults?
The recommended tool for locating faults is the PATURA Fence Compass. This combined volt­
age and current meter allows you to rapidly locate sources of current leakage. Alternatively,
use a PATURA DVM or Fence Tester. Use cut­out switches to turn off the power to different
sections of the electric fence. If the voltage on the fence increases when a section of the electric
fence is turned off, then investigate that section for possible faults.
There are no lights flashing on the energiser.
Check the power supply. Ensure that the power is switched on. If the energiser still does not
operate, request your PATURA service agent to check the energiser.

Servicing

This energiser contains no user serviceable parts. It must be returned to a PATURA­appointed
service agent for repair.

Product Specifications

Power Supply (12,6 V)
Power Consumption
Fast–Full Power
Fast–Half Power
Slow–Half Power
Output voltage
No Load
500 ohms
Max. Output energy
Stored energy
Dimensions (WxHxD)
Weight
PATURA GmbH •
Mainblick 1
63925 Laudenbach • Germany
P100
11­15 V dc
70 mA
35 mA
25 mA
7.8 kV
3.9 kV
0.6 J at 1000 ohms 1.2 J at 300 ohms 2.6 J at 200 ohms
0.8 J
200x170x90 mm
1.22 kg
%
+49(0)9372-94740
Fax +49(0)9372-947429
- 48 -
P200
11­15 V dc
140 mA
70 mA
45 mA
8.3 kV
5.3 kV
1.7 J
200x170x90 mm
1.22 kg
info@patura.com
www.patura.com
P300
11­15 V dc
340 mA
170 mA
100 mA
8.5 kV
5.7 kV
4.3 J
200x170x90 mm
1.22 kg