Fence is heavily loaded and needs urgent attention.
Selector switch
The energiser operates according to the position of the selector switch.
The selector switch controls the power output and pulse speed settings of the PATURA energiser.
Setting
Half Power/Fast Pulse
Half Power/Slow Pulse
Off
Full Power/Slow Pulse
Full Power/Fast Pulse
Full Power with Battery Test
Battery power conservation
When the battery charge level falls to low, the energiser will continue to operate at the select­
ed output power, but pulsing will automatically drop to very slow speed (approx. 3 seconds
be tween pulses). If the battery is still not recharged, the energiser will shut off (total discharge
protection).
Battery test setting
When the selector switch is set to "Full power with battery test", the indicator lights show the
charge level of the battery and other battery information. The battery test is only relevant when
Description
The energiser is operating at half output power
and is pulsing at fast speed (approx. 1.5 seconds
between pulses).
The energiser is operating at half output power
and is pulsing at slow speed (approx. 2.5
seconds between pulses).
The energiser is off and is not operating.
The energiser is operating at full output power
and is pulsing at fast speed (approx. 2.5 seconds
between pulses).
The energiser is operating at full output power
and is pulsing at fast speed (approx. 1.5 seconds
between pulses).
The energiser is operating at full output power, but
indicator lights show the battery level.
See "Battery test setting" below for
an explanation of the indicator lights.