is protected from animals and the environment. If necessary, house the energiser in a pro­
tective box. Consider site access, proximity to a suitable area for earthing and whether the
energiser is safe from human interference. Try
to position the energiser as near as possible to
the centre of the electric fence.
For installations in buildings without fire risk
make sure the energiser and battery are level.
Mount them above floor level and out of reach
of children.
Attention:
• Do not connect to mains-operated or line-operated equipment
• Remove the battery from the energiser before recharging the battery
• When charging the battery ensure that there is adequate ventilation to allow gases to dis­
perse.
Battery energisers with solar panels
Selection, installation and positioning of the solar panel. Refer to the "PATURA Electric Fencing
Catalogue" for information about selecting components, assembling and positioning a solar
energiser system.

Operation

• Keep this manual in a handy location.
• Carefully read all the safety considerations starting on page 44.
• Carefully check your installation to ensure that it complies with all local safety regulations.
Select the output setting using the selector switch (see "Selector switch" on page 38). One of
the three output performance indicator lights will flash with each pulse. The indicator lights
signal the approximate voltage at the output terminals, except when the selector switch is set to
"Full power with battery test".
Recommended.
Indicates a load on the energiser.
Attention required to ensure reliable animal control
Feedline to fence
Earth system
- 37 -
Note: Sleeve in wall
Joint clamp
to prevent chaffing
Insulated
high voltage
cable