ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly aware of the normative regulations and which
respects them scrupulously.
 Protection against the parts under tension must be ensured after the building-in.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for example:
circuit breakers, fuses or contactors.
Caution!
This appliance has only to be connected to a network 230 V~ 50 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
230V~1P+N 50Hz
400V~2P+N 50Hz
* calculated with the simultaneous factor following the standard EN 60 335-2-6/1990
Connection of the hob
The ceramic hob can be connected in different ways:
Monophase 230V~1P+N
Biphase
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the bridge between terminal 1 and 2 and between 4 and 5.
Attach the earth to the terminat "earth", the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminat "earth", the neutral N to terminal 4, the Phase L1 to the terminals
1 and the Phase L2 to the terminal 2.
Caution! Ensure that you:
- Correctly attach the wires and the bridges.
- Tighten the screws properly.
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
Connection
Cable diameter
1 Phase + N
3 x 2.5 mm²
2 Phases + N
4 x 1.5 mm²
400V~2P+N
equipped with a faulty earth connection
Cable
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
54
Protection calibre
25 A *
16 A *