5
Commissioning
Wrong operation and insufficient combustion of fuel brings to a damage of the product.
The control of the AGURO pellet stove is very easy. Control elements of the pellet stove are displayed in Fig. 8.
Fig. №. 8
5.1
Opening of the pellet stove door
The stove has two doors. The cast-iron door separates the heating chamber from other environment, and the glassed one is decorative and
completes the pellet stove design.
Be particular about sealing surfaces of the inner frame of the cast-iron door to ensure their easiest closing. The cast-iron door can be opened
with help of a handle; the decorative door can be opened by means of a clip and a magnet (they are a part of delivery). Observe cleanness of
the both doors.
The both doors always during stove operation have to be closed, otherwise the stove wouldn't work correctly and can be damaged!
If necessary, always open the cast-iron door slowly and carefully, in order to avoid sudden change of pressure in the heating chamber and
escape of smoke into the room.
5.2
Safety instructions
At handling and unpacking, be careful and observe safety instructions!
In case that there is a danger of occurrence of flammable gases for the temporary period in the room with an installed stove (for
example, during gluing of linoleum, at painting work, etc.), the pellet stove has to be put out of operation even before
occurrence of this danger!
During burning of the surface painting of the stove at the first firing-up, it is necessary to ventilate all the time and bring
sufficient quantity of fresh air into the room!
At operation it is necessary to provide sufficient supply of combustion air and safety withdrawal of flue gases!
The both doors have to be always closed!
The pellet stove may only be operated by a capable adult person!
Ensure that children, persons with mental disabilities and domestic animals cannot get to the space of the furnace itself or very
hot parts during operation of the stove (doors, glass, side covers, the furnace cover, etc.) – danger of burning and possible life
danger!
For the entire period of operation, fire in the stove has to be regularly checked!
In case of simultaneous operation of other heating device in the same room, it is necessary to ensure sufficient ventilation!
Don't touch the outer surfaces of the stove – danger of burning and possible life danger, except of control and regulating
elements!
Never extinguish fire in the pellet stove by water!
Ash from the ash-pan has to be removed carefully and with using of protective equipment, and only when the pellet stove is out
of operation!
Put ash into inflammable vessels with a cover!
The consumer mustn't be used for combustion of waste, rubbish; and no liquid fuels can be used in any combination! Use only
recommended fuels.
In case of occurrence of a fire of deposits in the chimney, extinguish quickly the fire in the stove by a dry-power extinguisher or
by sand, remove all flammable material situated near the stove and the chimney body. Close the door, control elements of the
stove and the smoke regulating shutter (if it is installed) and immediately announce the fire to a fire-fighting service!
Ensure performance of inspection of the pellet stove and flue-gas channel, including the chimney by a qualified person before
repeated commissioning!
It is not allowed to perform any modification of the product, except of mounting and service works performed by qualified
persons.
It is possible to use only spare parts approved by the manufacturer for repairs.
In case of non-observance of these conditions, a user loses a right to guarantee repairs.
All manuals and user guides at all-guides.com
91
Navigation in menu „UP", increase the value
Navigation in menu „DOWN", decrease the value
Button in menu „EXIT"
Button in menu „CONFIRM"
Button in menu „ON/OFF" or „CONFIRM"