Assembly instruction of the superstructure of model Gemma
Proceed according to the following sequence:
Insert the curved glass panels centering them accurately on the aluminum profile (FIG. 10a and 10b page 3).
-
Position the glass end walls in their housing, fasten them using the end covers on the outside part of the
-
superstructure (FIG. 11 page 3).
If necessary, you can multiplex the cabinet as described in par. 18.
Complete assembly of the cabinet by applying the front bottom plate (not necessary if the cabinet is on legs) the top glass
shelf and the anti-mist glass in fan assisted version.
The interior surfaces (bottom shelves, air intake and delivery strips, etc.) as well as the external surfaces (front trims and
counter in stainless steel, etc.) are covered with a protective film that has to be removed before starting to use the
cabinet.
For cabinets with remote compressor, subject to "Sanitation USA" regulations (NSF, UL, ETL etc.), the refrigerated
display must be sealed to the floor along the entire perimeter.
6 - Electric connection
Important: installation should be made following the manufacturer's instructions, by qualified personnel only, in
conformity with the electric safety regulations in force. Please refer to the electrical diagrams from page 10 to page 14.
At the input of the supply it is necessary to install an omni-polar magnetothermic/differential device with contact opening
equal to 3 mm and adequate cutoff power.
Caution: Before connecting the cabinet to the power mains make sure the supply voltage corresponds to the rating on
the serial number plate (consider that the maximum voltage variations admissible are +/- 10%). Both plug-in and remote
unit cabinets are delivered without the supply cable, therefore make sure the electric connection is made with cables of a
diameter and length capable of withstanding the power and current absorbed by the display cabinet (TAB. 2 page 4).
Important: installation should be made following the manufacturer's instructions, by qualified personnel only, in
conformity with the electric safety regulations in force in the country where the cabinet is installed (electric safety
regulations and laws, accident prevention laws, fire prevention regulations, directives).
Always ground the cabinet.
The manufacturer is not liable for any injuries caused by failure to respect this regulation.
If there is no wall socket near where the cabinet is to be installed, provide for connection in conformity with the regulations
in force.
Do not use adapter plugs.
The manufacturer has no liability for any damage to personnel or property caused by improper installation.
7 - Technical features
The cabinet is supplied with a plastic bag containing this manual of instructions that must be kept. It contains technical
data, wiring diagrams and tables concerning the cabinet.
The technical data are also shown on the rating plate (FIG. 13 page 4). It indicates:
1. Name and address of the manufacturer
2. Commercial name of the cabinet
3. Cabinet code
4. Cabinet serial number
5. Rating
6. Frequency
7. Max absorbed current
8. Max absorbed power
9. Max absorbed power during defrosting
10. Standard lighting power
11. Net display area
12. Type of cooling gas used
13. Weight of cooling gas loaded in each unit
14. Climate class and reference temperature (dry bulb)
15. Electrical safety factor
16. Work schedule number
17. Work order number
18. Year of manufacture
19. Heating capacity
20. QR code
21. EAC marking
Important: The rating plate and warning labels should never be removed. The manufacturer is not liable for any damages
caused by failure to respect this regulation.
This is to certify that the product complies with Legislative Decree no. 108 of 25/01/1992 applying EEC Directive 89/109
concerning materials and objects expected to come into contact with food products.
8 - Filling with products and use of the cabinet (startup)
With the cabinet off, remove the plastic film protection on the inside and outside and clean the cabinet according to the
instructions in paragraph 11.